High Efficiency Filter Outlet HEPA Box With Smooth Diffuser Plate For Pharmaceutical Cleanroom

Brand Name : GCC

Certification : ISO9001,ISO14001,ISO45001,CE

Place of Origin : China

MOQ : 1

Price : 135$

Payment Terms : T/T

Supply Ability : Manufacturer

Delivery Time : 10-14

Packaging Details : Wooden Box

Filtration Efficiency : 99%

Size : 39*41*32CM

Keyword : Cleanroom Air Outlet

Material : Stailess Steel SUS304/201/Q195 /galvanized Sheet

Warranty : 1 year

Package Contents : 1 Air Filter Outlet

Application : Cleanroom

Color : White

Condition : New

Function : Air Purification

Weight : 34KG

Contact Now

The Seal HEPA Box for Pharmaceutical Cleanroom is made of high-quality cold-rolled steel plate. The surface is electrostatically sprayed,including static pressure tank, high-efficiency filter, diffuser plate, and a new level of clean room. It is used as a filter to clean the ceiling with less investment and simple construction. In order to ventilate the high-efficiency filter after obtaining the ideal static pressure, the high-efficiency filter is properly used. Compact structure, reliable performance, strong ventilation, easy installation and easy maintenance.
We are dust free design and manufacturer specialist, we have a R&D department,and have our own factory, also we have some long-time cooperated suppliers. For the whole dust free project, from design until the dust free plant installation,we will do one-stop service for you,and we will keep lifetime after sales service for your dust free project, all products for dust free we are provide for you, as clean room, air shower room, pass box, ect.

Application:
The terminal air filtration equipment used for the newly-purified 1000-, 10,000-, 100,000-class and clean room purification projects meets the requirements of purification requirements, and can be widely used in the purification of air-conditioning systems in the pharmaceutical, sanitary, electronics, and chemical industries.

Core Advantages:

1.The surface of the box is treated with electrostatic spray.
2.The tank seal design further enhances its uniqueness
3.Strong corrosion resistance
Material: color steel plate or galvanized sheet spray.
Tips:can be customized according to requirements

Main Technical Parameter:

Product Air Diffuser With Net Air Supply Unit Outlet Air Hepa Filter Box
Technology Purification Engineering
Body install Size 370*370*370;534*534*370;660*660*370,965*625*370;1270*660*370mm
Outlet top size 434*434*370;588*588*370;744*744*370;1334*724*370;1374*744*370mm
Frame Material SUS Aluminum/Stainless Steel
Rated Air Flow 500;1000;1500;2000;3000m3/h
Type Stainless Steel Work Surface,PMMA enclosure,can be equipped with ultraviolet lamp
remote control electrical interface.
Frame Stainless Steel
HS CODE 8421399090
Filter efficiency 99.99%@0.3um
Color Ivory white

FAQ:

1. What is the function of a high-efficiency air supply outlet?

High-efficiency air supply outlets are critical components of cleanroom ventilation systems, equipped with HEPA or ULPA filters.
They are designed to:
* Filter airborne particles (≥99.97% efficiency for particles ≥0.3μm)
* Distribute clean air uniformly (maintaining unidirectional or mixed airflow)
* Control pressure differential and air exchange rates (ensuring ISO cleanliness standards)
2. How often should the filters in high-efficiency air supply outlets be replaced?
Replacement intervals depend on the operating environment. General recommendations:
* Pre-filters: Inspect/replace every 3-6 months
* HEPA filters: Replace every 2-5 years (or when pressure drop alarms trigger)
Key influencing factors:
✔ Air pollution levels (e.g., pathogen-containing aerosols in pathology labs may require shorter cycles)
✔ Operational hours (24/7 use demands more frequent maintenance)
✔ Pressure differential data (replace when ΔP ≥ 1.5× initial value)
3. How to determine if a high-efficiency air supply outlet has failed?
Testing methods:
* Pressure monitoring: Significant drop in ΔP across the outlet (indicating possible damage)
* Particle counting: Downstream particle counts exceeding standards (e.g., >3,520 particles/m³ for ≥0.5μm in ISO Class 5)
* DOP/PAO leak testing: Scan filter edges and media; >0.01% leakage rate indicates failure


Product Tags:

Pharmaceutical Cleanroom HEPA Box

      

Smooth Diffuser Plate HEPA Box

      

High Efficiency Filter Outlet HEPA Box

      
Wholesale High Efficiency Filter Outlet HEPA Box With Smooth Diffuser Plate For Pharmaceutical Cleanroom from china suppliers

High Efficiency Filter Outlet HEPA Box With Smooth Diffuser Plate For Pharmaceutical Cleanroom Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou Cleanroom Construction Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)